					测量范围 | 
					离子浓度 | 
					0.00~14.00pX | 
| 
					pH | 
					(-2.000~19.999)pH | |
| 
					mV | 
					-1999.9mV~0~1999.9mV | |
| 
					温度 | 
					(-10~110)℃ | |
| 
					电导率 | 
					0.00µS/cm~2000 mS/cm 包括: 
					(0.00~20.00)µS/cm 
					(20.0~200.0)µS/cm 
					(200~2000)µS/cm  
					(2.00~20.00)mS/cm 
					(20.0~200.0)mS/cm  
					(200~2000)mS/cm | |
| 
					电阻率 | 
					(0~100)MΩ·cm | |
| 
					TDS | 
					(0~100) g/L | |
| 
					盐度 | 
					(0~100) ppt | |
| 
					溶解氧 | 
					(0~20.0)mg/L(ppm) | |
| 
					溶解氧饱和度 | 
					(0.0~200.0)% | |
| 
					温度 | 
					(-10~110) ℃ | |
| 
					分辨率 | 
					离子浓度 | 
					0.01 pX,0.01mol/L,0.01mg/L,0.01ppm | 
| 
					pH | 
					0.001 pH | |
| 
					mV | 
					0.1 mV | |
| 
					电导率 | 
					0.01/0.1/1µS/cm;0.01/0.1/1mS/cm | |
| 
					溶解氧 | 
					0.1mg/L | |
| 
					溶解氧饱和度 | 
					1/0.1% | |
| 
					温度 | 
					 | |
| 
					基本误差 | 
					离子浓度 | 
					±0.01 pX(一介) ±0.02 pX(二介) | 
| 
					pH | 
					±0.002 pH | |
| 
					mV | 
					±0.03%FS | |
| 
					电导率 | 
					±0.5%FS | |
| 
					溶解氧 | 
					±0.3mg/L | |
| 
					温度 | 
					± | |
| 
					响应时间 | 
					30s( | |
| 
					残留电流 | 
					0.1mg/L | |
●离子测量:有十种常用离子可供选择,也可以自定义其他离子
●pH一至五点自动校正,电导率一至四点自动校正,离子二至五点自动校正,有校正指引和自动检查功能
●pH自动/手动(0~100)℃温度补偿;离子自动/手动(0~60)℃温度补偿,电导率自动/手动(0~50)℃温度补偿功能
●离子单位可自行选择和切换pX、mol/L、mg/L和ppm
●电导率高纯水测量模式,基准温度选择,电极常数选择,温度补偿系数选择
			●溶解氧(0~45)℃自动温度补偿,0~45ppt自动盐度补偿
			●80~105kPa自动气压补偿,校准套水饱和空气自动校正
			●具数据稳定显示模式
●符合GLP数据管理模式,数据存储300组(手动和自动存储),具USB通讯接口
●pH标准溶液选择(中国标准、欧美标准、NIS标准和自定义)
			●具高纯水pH测量模式和加氨纯水pH测量模式
●具EH氧化还原电位测量模式
●温度单位选择(℃和℉)
			●可恢复出厂值设置
			●90×
●符合IP54防尘防溅等级,仪表插口有橡胶帽密封保护
●配置有盐度补偿的溶氧电极,电极校准套和智能搅拌器